# INC — Increment by 1
|
||
|
||
## Description
|
||
|
||
Adds 1 to the destination operand, while preserving the state of the CF flag. The destination operand can be a register or a memory location.
|
||
This instruction allows a loop counter to be updated without disturbing the CF flag. Use a ADD instruction with an immediate operand of 1 to
|
||
perform an increment operation that does updates the CF flag.
|
||
|
||
## Instruction
|
||
|
||
| Opcode | Assembly | Op/En | Modern Mode | Legacy Mode | Description |
|
||
|---------------|-----------|-------|-------------|-------------|------------------------------------------------------------------------------|
|
||
| FE /0 | INC r/m8 | M | Valid | Valid | Increment r/m byte by 1. |
|
||
| REX + FE /0 | INC r/m8* | M | Valid | N.E. | Increment r/m byte by 1. |
|
||
| FF /0 | INC r/m16 | M | Valid | Valid | Increment r/m word by 1. |
|
||
| FF /0 | INC r/m32 | M | Valid | Valid | Increment r/m doubleword by 1. |
|
||
| REX.W + FF /0 | INC r/m64 | M | Valid | N.E. | Increment r/m quadword by 1. |
|
||
| 40+ rw** | INC r16 | O | N.E. | Valid | Increment word register by 1. |
|
||
| 40+ rd | INC r32 | O | N.E. | Valid | Increment doubleword register by 1. |
|
||
|
||
- In 64-bit mode, r/m8 can not be encoded to access the following byte registers if a REX prefix is used: AH, BH, CH, DH.
|
||
|
||
- 40H through 47H are REX prefixes in 64-bit mode.
|
||
|
||
## Information
|
||
|
||
This instruction can be used with a LOCK prefix to allow the instruction to be executed atomically.
|
||
|
||
In 64-bit mode, INC r16 and INC r32 are not encodable (because opcodes 40H through 47H are REX prefixes). Otherwise, the instruction’s 64-bit
|
||
mode default operation size is 32 bits. Use of the REX.R prefix permits access to additional registers (R8-R15). Use of the REX.W prefix
|
||